Eomix
Premix Condensing Wall Hung Gas Boilers
- Specially Developed Silencer
- Environmentally Friendly
- Ergonomic, Aesthetic and User Friendly Control Panel
- Lower Fuel Consumption with Intelligent Adaptation System
-
Guarantee2 Years *Only valid in Türkiye
-
Energy Efficiency ClassA Class
-
Ease of Installation and Maintenance
-
Capacity Options20 – 24 – 35 kW
-
Sound Level49 dB
-
Compact Dimensions400 mm x 600 mm x 320 mm
-
General Features

Silent Operation with Special Advanced Silencer
It works by minimising the operating noise that may occur thanks to the specially designed silencer used at the fresh air duct inlet.

Wide Modulation Range
With the gas valve with a wide modulation range, stop-start operation of the burner is prevented by adjusting its capacity according to the need, heating comfort is increased, system losses are minimised and harmful substance emissions during ignition are reduced.

Smart Adaptation System
Eomix combi boilers recognise the climatic conditions of the region and the house thanks to the smart adaptation system. Accordingly, despite all factors affecting temperature variations, it determines the optimum operating conditions and adapts itself to different environmental conditions. Thus, it provides maximum efficiency by working with maximum performance with less gas consumption.
-
Complete Insulation
Thanks to its interior completely covered with soft insulation material for heat and sound insulation, it operates extremely quietly and reduces the heat loss emitted from the body.
-
Low Pressure Feature
Thanks to the gas control system, it operates with high performance even in case of low gas inlet pressure.
-
14 Different Safety Systems
COPA Eomix boilers have 14 different safety systems. In this way, it works with high performance, safe and long-lasting.
-
Freeze Protection Feature
Thanks to the protection feature that automatically activates according to the values taken from the sensors inside, it prevents the installation from freezing and protects the boiler and installation against any damage.
-
Digital Capacity Setting
Different capacity settings can be made according to the size of the house and heat loss. COPA Eomix combi boilers, which are digitally adjusted to thermal power very precisely, provide high efficiency by spending power at the rate of need instead of excess thermal power.
-
Double Manometer
Water pressure can be easily observed both digitally on the LCD screen and mechanically on the product with the manometer.
-
Eco / Comfort Mode
Via the e/c button on the Eomix control panel; More efficient heating is provided with Eco mode and shorter heating time is provided with Comfort mode.
-
Ekopanel Feature with Outdoor Air Sensor Connection
Thanks to the software on the circuit board, an outdoor air sensor can be optionally connected. In this way, in combi boilers that turn into economy panels, the radiator return water temperature is adjusted depending on the outside air temperature. While this system guarantees maximum thermal comfort, it also saves energy by preventing temperature fluctuations.
-
-
Technical Specs
MODEL EOMIX 20 EOMIX 24 EOMIX 35 Seasonal Space Heating Energy Class A A A Energy Efficiency (ηs) % 92 92 93 Useful Efficiency at Nominal Heat Output and High Temperature Regime² (η4) % 87,4 87,8 88,3 Useful Efficiency at 30% of Nominal Heat Output and Low Temperature Regime¹ (η1) % 97,3 97,5 97,8 Useful Heat Output at Nominal Heat Output and High Temperature Regime² (P4) kW 20,1 24,1 27,5 Useful Heat Output at 30% of Nominal Heat Output and Low Temperature Regime¹ (P1) kW 8,1 8,1 8,1 Rated Heat Output (Prated) (80-60°C) kW 20 24 28 Heat Output Pn (50/30°C) Min/Max kW 4,1/21,9 4,5/25,5 5,2/30 Daily Electricity Consumption Qelec kWh 0,135 0,133 0,132 Daily Gas Consumption Qfuel kWh 23,9 21,856 22,195 Annual Energy Consumption for Space Heating GJ 42 51 58 Heating Circuit Operating Pressure Min/Max bar 0,4 / 3 0,4 / 3 0,4 / 3 Heating Circuit Temperature Adjustment Range Min/Max °C 30/85 Expansion Vessel Volume Liter 8 DHW Heating Energy Efficiency Class A Declared Load Profile XL Energy Efficiency % 85 Annual Electricity Consumption kWh 30 Annual Fuel Consumption GJ 19 DHW Heat Load Min/Max kW 4,1/23,7 4,1/28,1 4,7/33,5 DHW (ΔT:30 °C) Min/Max L/min 2/11,4 2/13,5 2/16,1 DHW Circuit Temperature Adjustment Range Min/Max °C 30 / 65 Domestic Water Pressure Min/Max bar 0,4/10 0,4/10 0,4/14 Electricity Consumption (At Full Load) elmax kW 0,029 0,029 0,033 Electricity Consumption (At Partial Load) elmin kW 0,014 0,016 0,013 Electricity Consumption (In Standby Mode) PSB kW 0,002 0,002 0,002 Heat Loss in Standby Mode Pstby kW 0,057 0,060 0,056 Power Supply V / Hz 220-240 / 50 Protection Index IP IPX4D NOx Weight mg/kWh 36 39 42 NOx Class 6 Gas Category II2H3+ Gas Inlet Pressure G20 / G25 mbar 20 / 28 20 / 28 20 / 28 Gas Consumption (Natural Gas) Min/Max m³/h 0,60/2,5 0,65/2,65 0,7/3,03 Flue Types C13 - C23 - C33 - C43 - C53 - B3 Standard Flue Size mm 60 / 100 Standard Pipe Length mm 800 Maximum Flue Application Distance: Horizontal 60 / 100 m 6 Maximum Flue Application Distance: Vertical 80 / 125 m 20 Flue Gas Temperature (80/60 °C) Min/Max °C 75 / 85 75 / 85 75 / 85 Flue Gas Temperature (50/30 °C) Min/Max °C 48/53 51/55 52/57 Maximum Flue Gas Temperature [At Maximum Domestic Hot Water Mode] °C 55 55 55 Sound Level dB (A) 49 49 49 Device Weight Net kg 28,5 29 31,5 Dimensions Width mm 400 400 400 Height mm 600 600 600 Depth mm 320 320 320